The Perfect Toxic Storm!!!

ONE SIMPLE QUESTION: Is there ANY known construction model, according to code, which would account for the following situation...

A 30+ year old building of over 100 units throughout seven floors in the US, was renovated approximately 5 to 6 years ago, and adapted to a little over 80 units overall, in a senior housing complex, intended for a known population of sick, elderly, immune-compromised seniors.

All but two of the units, were one bedrooms, serviced by in-the-wall window air conditioning units, with the other two units being two bedroom apartments, on the first and second floors only, respectively stacked on top of each other, and each serviced by three (3) ceiling Mitsubishi commercial HVAC units.

In the apartment on the second floor, after a period of time, there was found to be not one, not two, but seemingly three HVAC units that would overtime, have the units build up and overflow what would otherwise have been year-by year concentrating toxic fungal/ contagious bacterial build-ups, due to construction negligence, whereby the approximate 1/4 inch-1/2 inch pvc drain hose was found to be crimped, bent into a U-shape, and jammed into the wall pointing upward.

It was only after this situation occurred, in each of the two HVAC units (Master bedroom & living room), that adaptations were made which included hard plastic PVC piping of approximately 1 inch in diameter, I will share a information to the back of the units, for a seemingly normal drain pattern along the exterior wall and draining off the balcony approximately 12 feet away.

SPECIAL NOTE: It was prior to this adaptation, that as a lay person and consumer viewing these problems, it was simply assumed that the bent/crimped plastic hose jammed into the wall pointing upward, was otherwise intended to have been draining within the approximate 4-6 inch space between the interior and exterior wall, and leading down to the first floor, where there might have been a drain to accommodate the continual flow of water that would be a normal part of the proper functioning of these HVAC units.

QUESTION: Is there any known building design of over 30 years ago, according to code, that would accommodate and lead to a drain within the interior/ exterior wall space, and allow for the proper draining of this retrofitted and highly modern HVAC unit???

Or do you believe, the only possibility and reason for the years-later adaptation of 1 inch hard plastic PVC piping on the exterior wall and outside the building after each overflow, would have been because those soft plastic bent/crimped hoses left pointing upward were simply left unconnected to any intended external and adapted draining method???


About the recuiter
Member since Mar 14, 2020
Techsunware Inc
from Surhondar, Uzbekistan

Skills & Expertise Required

Legal 

Open for hiringApply before - Aug 16, 2024

Work from Anywhere

40 hrs / week

Hourly Type

Remote Job

$21.01

Cost

Offer to work on this project closes in 13 days!
Are you interested in this Opportunity?

Looking for help? Checkout our video tutorial
How to search and apply for jobs

How to apply? Do you have more questions about the Job?
See frequently asked questions

Similar Projects

Checking GDPR Compatibility of the Privacy Policy

We have a Privacy Policy. We need to make sure it is GDPR compatible. We need it to be reviewed and made necessary changes for GDPR compliance.

Need attorney to file trademark with follow up

I need an attorney to register a trademark and do all required follow up

Need a website design

Modern. Professional and Elegant Design with Technology, not a classic Law firm template
Good marketing content (a lot of content can be provided)
Editable design as to add and remove niche services
Easy and efficient blog tool for Articl...read more

Paralegal needed

Paralegal needed for healthcare, ketamine clinic start-up. Paralegal needed to draft policies, documents, compliance regulations etc..

Demand Letter Writing, of counsel

Legal startup is looking for a licensed and active attorney to write demand letters for demand letter platform in an of counsel capacity.

The types of letters are wide ranging: Intent to sue neighbors, town/municipalities, tenants/landlord...read more